Slip ratio (gas–liquid flow)

From Wikipedia, the free encyclopedia

Slip ratio (or velocity ratio) in gas–liquid (two-phase) flow, is defined as the ratio of the velocity of the gas phase to the velocity of the liquid phase.[1]

In the homogeneous model of two-phase flow, the slip ratio is by definition assumed to be unity (no slip). It is however experimentally observed that the velocity of the gas and liquid phases can be significantly different, depending on the flow pattern (e.g. plug flow, annular flow, bubble flow, stratified flow, slug flow, churn flow). The models that account for the existence of the slip are called "separated flow models".

The following identities can be written using the interrelated definitions:

where:

  • S – slip ratio, dimensionless
  • indices G and L refer to the gas and the liquid phase, respectively
  • u – velocity, m/s
  • U – superficial velocity, m/s
  • void fraction, dimensionless
  • ρ – density of a phase, kg/m3
  • x – steam quality, dimensionless.

YouTube Encyclopedic

  • 1/3
    Views:
    2 263
    708 005
    37 013
  • Chapter 8 Tutorial: Ratio Control
  • Blood Vessels, part 1 - Form and Function: Crash Course A&P #27
  • Lec-17 Laminar and Turbulent Flows

Transcription

Correlations for the slip ratio

There are a number of correlations for slip ratio.

For homogeneous flow, S = 1 (i.e. there is no slip).

The Chisholm correlation[2][3] is:

The Chisholm correlation is based on application of the simple annular flow model and equates the frictional pressure drops in the liquid and the gas phase.

The slip ratio for two-phase cross-flow horizontal tube bundles may be determined using the following correlation:

where the Richardson and capillary numbers are defined as and .[4]

For enhanced surfaces bundles the slip ratio can be defined as:

[5]

Where:

  • S – slip ratio, dimensionless
  • P – tube centerline pitch
  • D – tube diameter
  • Subscript – liquid phase
  • Subscript – gas phase
  • g– gravitational acceleration
  • – minimum distance between the tubes
  • G-mass flux (mass flow per unit area)
  • – dynamic viscosity
  • – surface tension
  • – thermodynamic quality
  • – void fraction

References

  1. ^ G.F. Hewitt, G.L. Shires, Y.V.Polezhaev (editors), "International Encyclopedia of Heat and Mass Transfer," CRC Press, 1997.
  2. ^ D. Chisholm, "Two-Phase Flow in Pipelines and Heat Exchangers", Longman Higher Education, 1983. ISBN 0-7114-5748-4
  3. ^ John R. Thome, "Wolverine Heat Transfer Engineering Data book III," Wolverine Tube Inc, 2004, Chapter 17 "Heat Transfer Databooks | Products | Wolverine Tube Inc". Archived from the original on 2010-04-29. Retrieved 2010-05-03..
  4. ^ Feenstra, P. A.; Weaver, D. S.; Judd, R. L. (2000-11-01). "An improved void fraction model for two-phase cross-flow in horizontal tube bundles". International Journal of Multiphase Flow. 26 (11): 1851–1873. doi:10.1016/S0301-9322(99)00118-4.
  5. ^ Gorgy, Evraam; Eckels, Steven (2016-08-01). "Convective boiling of R-134a on enhanced-tube bundles". International Journal of Refrigeration. 68: 145–160. doi:10.1016/j.ijrefrig.2016.04.010. hdl:2097/39382.
This page was last edited on 20 August 2022, at 21:32
Basis of this page is in Wikipedia. Text is available under the CC BY-SA 3.0 Unported License. Non-text media are available under their specified licenses. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc. WIKI 2 is an independent company and has no affiliation with Wikimedia Foundation.