To install click the Add extension button. That's it.

The source code for the WIKI 2 extension is being checked by specialists of the Mozilla Foundation, Google, and Apple. You could also do it yourself at any point in time.

4,5
Kelly Slayton
Congratulations on this excellent venture… what a great idea!
Alexander Grigorievskiy
I use WIKI 2 every day and almost forgot how the original Wikipedia looks like.
Live Statistics
English Articles
Improved in 24 Hours
Added in 24 Hours
Languages
Recent
Show all languages
What we do. Every page goes through several hundred of perfecting techniques; in live mode. Quite the same Wikipedia. Just better.
.
Leo
Newton
Brights
Milds

Pole–zero plot

From Wikipedia, the free encyclopedia

In mathematics, signal processing and control theory, a pole–zero plot is a graphical representation of a rational transfer function in the complex plane which helps to convey certain properties of the system such as:

A pole-zero plot shows the location in the complex plane of the poles and zeros of the transfer function of a dynamic system, such as a controller, compensator, sensor, equalizer, filter, or communications channel. By convention, the poles of the system are indicated in the plot by an X while the zeros are indicated by a circle or O.

A pole-zero plot is plotted in the plane of a complex frequency domain, which can represent either a continuous-time or a discrete-time system:

  • Continuous-time systems use the Laplace transform and are plotted in the s-plane:
    • Real frequency components are along its vertical axis (the imaginary line where )
  • Discrete-time systems use the Z-transform and are plotted in the z-plane:

YouTube Encyclopedic

  • 1/5
    Views:
    271 523
    233 669
    131 889
    8 220
    27 003
  • Zeros and Poles of a Transfer Function
  • Intro to Control - 7.1 Poles and Zeros
  • Frequency Response Magnitude and Poles and Zeros
  • Representation of Poles and Zeros in S-Plane Problem 06 - Laplace Transform - Signals and Systems
  • Pole & Zero to Time Domain Response

Transcription

Continuous-time systems

In general, a rational transfer function for a continuous-time LTI system has the form:

where

  • and are polynomials in ,
  • is the order of the numerator polynomial,
  • is the th coefficient of the numerator polynomial,
  • is the order of the denominator polynomial, and
  • is the th coefficient of the denominator polynomial.

Either or or both may be zero, but in real systems, it should be the case that ; otherwise the gain would be unbounded at high frequencies.

Poles and zeros

  • the zeros of the system are roots of the numerator polynomial:
    such that
  • the poles of the system are roots of the denominator polynomial:
    such that

Region of convergence

The region of convergence (ROC) for a given continuous-time transfer function is a half-plane or vertical strip, either of which contains no poles. In general, the ROC is not unique, and the particular ROC in any given case depends on whether the system is causal or anti-causal.

The ROC is usually chosen to include the imaginary axis since it is important for most practical systems to have BIBO stability.

Example

This system has no (finite) zeros and two poles:

and

The pole-zero plot would be:

P-z plot of previously created example

Notice that these two poles are complex conjugates, which is the necessary and sufficient condition to have real-valued coefficients in the differential equation representing the system.

Discrete-time systems

In general, a rational transfer function for a discrete-time LTI system has the form:

where

  • is the order of the numerator polynomial,
  • is the th coefficient of the numerator polynomial,
  • is the order of the denominator polynomial, and
  • is the th coefficient of the denominator polynomial.

Either or or both may be zero.

Poles and zeros

  • such that are the zeros of the system
  • such that are the poles of the system.

Region of convergence

The region of convergence (ROC) for a given discrete-time transfer function is a disk or annulus which contains no uncancelled poles. In general, the ROC is not unique, and the particular ROC in any given case depends on whether the system is causal or anti-causal.

  • If the ROC includes the unit circle, then the system is bounded-input, bounded-output (BIBO) stable.
  • If the ROC extends outward from the pole with the largest (but not infinite) magnitude, then the system has a right-sided impulse response. If the ROC extends outward from the pole with the largest magnitude and there is no pole at infinity, then the system is causal.
  • If the ROC extends inward from the pole with the smallest (nonzero) magnitude, then the system is anti-causal.

The ROC is usually chosen to include the unit circle since it is important for most practical systems to have BIBO stability.

Example

If and are completely factored, their solution can be easily plotted in the z-plane. For example, given the following transfer function:

The only (finite) zero is located at: , and the two poles are located at: , where is the imaginary unit.

The pole–zero plot would be:

See also

Bibliography

  • Haag, Michael (June 22, 2005). "Understanding Pole/Zero Plots on the Z-Plane". OpenStax CNX. Retrieved June 9, 2018.[dead link]
  • Eric W. Weisstein. "Z-Transform". MathWorld. Retrieved January 24, 2010.
This page was last edited on 6 September 2023, at 18:29
Basis of this page is in Wikipedia. Text is available under the CC BY-SA 3.0 Unported License. Non-text media are available under their specified licenses. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc. WIKI 2 is an independent company and has no affiliation with Wikimedia Foundation.