To install click the Add extension button. That's it.

The source code for the WIKI 2 extension is being checked by specialists of the Mozilla Foundation, Google, and Apple. You could also do it yourself at any point in time.

4,5
Kelly Slayton
Congratulations on this excellent venture… what a great idea!
Alexander Grigorievskiy
I use WIKI 2 every day and almost forgot how the original Wikipedia looks like.
What we do. Every page goes through several hundred of perfecting techniques; in live mode. Quite the same Wikipedia. Just better.
.
Leo
Newton
Brights
Milds

Architectural acoustics

From Wikipedia, the free encyclopedia

Symphony Hall, Birmingham, an example of the application of architectural acoustics

Architectural acoustics (also known as building acoustics) is the science and engineering of achieving a good sound within a building and is a branch of acoustical engineering.[1] The first application of modern scientific methods to architectural acoustics was carried out by the American physicist Wallace Sabine in the Fogg Museum lecture room. He applied his newfound knowledge to the design of Symphony Hall, Boston.[2]

Architectural acoustics can be about achieving good speech intelligibility in a theatre, restaurant or railway station, enhancing the quality of music in a concert hall or recording studio, or suppressing noise to make offices and homes more productive and pleasant places to work and live in.[3] Architectural acoustic design is usually done by acoustic consultants.[4]

YouTube Encyclopedic

  • 1/5
    Views:
    95 286
    38 020
    321 240
    2 215 633
    8 036
  • Architectural Acoustics 1 of 4: Sound and Building Materials
  • Acoustics of Buildings
  • 5 Ancient Structures with Amazing Acoustics
  • How Sound Works (In Rooms)
  • Acoustic engineering: The art of engineering a silent world

Transcription

Building skin envelope

This science analyzes noise transmission from building exterior envelope to interior and vice versa. The main noise paths are roofs, eaves, walls, windows, door and penetrations. Sufficient control ensures space functionality and is often required based on building use and local municipal codes. An example would be providing a suitable design for a home which is to be constructed close to a high volume roadway, or under the flight path of a major airport, or of the airport itself.

Inter-space noise control

The science of limiting and/or controlling noise transmission from one building space to another to ensure space functionality and speech privacy. The typical sound paths are ceilings, room partitions, acoustic ceiling panels (such as wood dropped ceiling panels), doors, windows, flanking, ducting and other penetrations. Technical solutions depend on the source of the noise and the path of acoustic transmission, for example noise by steps or noise by (air, water) flow vibrations. An example would be providing suitable party wall design in an apartment complex to minimize the mutual disturbance due to noise by residents in adjacent apartments.

Inter-space noise control can take a different form when talking about Acoustics in European football stadiums. One goal in stadium acoustics is to make the crowd as loud as possible and inter-space noise control becomes a factor but in helping reflect noise to create more reverberation and louder decibel level throughout the stadium. Many outdoor soccer stadiums for example have roofs over the fan sections which create more reverberation and echoing which helps raise the general volume in the stadium.[5]

Interior space acoustics

Diffusers which scatter sound are used in some rooms to improve the acoustics

This is the science of controlling a room's surfaces based on sound absorbing and reflecting properties. Excessive reverberation time, which can be calculated, can lead to poor speech intelligibility.

Ceiling of Culture Palace (Tel Aviv) concert hall is covered with perforated metal panels

Sound reflections create standing waves that produce natural resonances that can be heard as a pleasant sensation or an annoying one.[6] Reflective surfaces can be angled and coordinated to provide good coverage of sound for a listener in a concert hall or music recital space. To illustrate this concept consider the difference between a modern large office meeting room or lecture theater and a traditional classroom with all hard surfaces.

An anechoic chamber, using acoustic absorption to create a dead space.

Interior building surfaces can be constructed of many different materials and finishes. Ideal acoustical panels are those without a face or finish material that interferes with the acoustical infill or substrate. Fabric covered panels are one way to heighten acoustical absorption. Perforated metal also shows sound absorbing qualities.[7] Finish material is used to cover over the acoustical substrate. Mineral fiber board, or Micore, is a commonly used acoustical substrate. Finish materials often consist of fabric, wood or acoustical tile. Fabric can be wrapped around substrates to create what is referred to as a "pre-fabricated panel" and often provides good noise absorption if laid onto a wall.

Prefabricated panels are limited to the size of the substrate ranging from 2 by 4 feet (0.61 m × 1.22 m) to 4 by 10 feet (1.2 m × 3.0 m). Fabric retained in a wall-mounted perimeter track system, is referred to as "on-site acoustical wall panels". This is constructed by framing the perimeter track into shape, infilling the acoustical substrate and then stretching and tucking the fabric into the perimeter frame system. On-site wall panels can be constructed to accommodate door frames, baseboard, or any other intrusion. Large panels (generally, greater than 50 square feet (4.6 m2)) can be created on walls and ceilings with this method. Wood finishes can consist of punched or routed slots and provide a natural look to the interior space, although acoustical absorption may not be great.

There are four ways to improve workplace acoustics and solve workplace sound problems – the ABCDs.

  • A = Absorb (via drapes, carpets, ceiling tiles, etc.)
  • B = Block (via panels, walls, floors, ceilings and layout)
  • C = Cover-up, or Control (background sound levels and spectra) (via masking sound)
  • D = Diffuse (cause the sound energy to spread by radiating in many directions)

Mechanical equipment noise

Building services noise control is the science of controlling noise produced by:

  • HVAC (heating, ventilation, air conditioning) systems
  • Elevators
  • Electrical generators positioned within or attached to a building
  • Any other building service infrastructure component that emits sound.

Inadequate control may lead to elevated sound levels within the space which can be annoying and reduce speech intelligibility. Typical improvements are vibration isolation of mechanical equipment, and sound attenuators in ductwork. Sound masking can also be created by adjusting HVAC noise to a predetermined level.

See also

References

  1. ^ Morfey, Christopher (2001). Dictionary of Acoustics. Academic Press. p. 32.
  2. ^ Sabine, Wallace Clement (1922). Collected papers on acoustics. Harvard University Press.
  3. ^ Templeton, Duncan (1993). Acoustics in the Built Environment: Advice for the Design Team. Architectural Press. ISBN 978-0750605380.
  4. ^ National Careers Service. "Job profiles Acoustics consultant"..
  5. ^ "How do you give stadiums atmosphere?". BBC News. 2013-04-12. Retrieved 2021-05-10.
  6. ^ Glen Ballou & Howards Sams, editors. "Handbook for Sound Engineers", page 56.
  7. ^ Stewart, William (2007). "Perforated metal systems as sound absorbing surfaces" (PDF). February. {{cite journal}}: Cite journal requires |journal= (help)

Further reading

This page was last edited on 1 July 2022, at 21:07
Basis of this page is in Wikipedia. Text is available under the CC BY-SA 3.0 Unported License. Non-text media are available under their specified licenses. Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc. WIKI 2 is an independent company and has no affiliation with Wikimedia Foundation.